AEM hydrogen generator
The AEM hydrogen generator is an efficient hydrogen production equipment based on AEM (Anion Exchange Membrane) technology. This technology combines the high efficiency and selectivity of PEM (proton exchange membrane) with the low-cost advantage of ALK (alkaline electrolysis cell), without the need for precious metals, low maintenance costs, and low water quality requirements. Our independently developed AEM hydrogen generator adopts a self-developed AEM electrolytic cell, equipped with multi-stage purification technology, and has functions such as automatic anti reflux, automatic flow tracking, and self sleep. It has the advantages of low cost, high efficiency, long life, and high purity
Application:
1.GC (gas chromatography) fuel gas and carrier gas(replace h2 cylinder)
2.ICP-MS reaction gas
3.ELCD (conductivity detector) reaction h2 gas(replace h2 cylinder)
4.AED (atomic emission detector) of the reaction h2 gas(replace h2 cylinder)
5.Pure h2 gas supply for fuel cell
6.Other pure h2 using field
Technical Parameter:
|
Type |
SQ-300 |
|
Output Volume (ml/min) |
0~300 |
|
Output Pressure (MPa) |
0.15~0.4 |
|
H2 purity (%) |
>99.999 |
|
Protective Pressure (MPa) |
0.46 |
|
Power Voltage (V) |
220±15% 110±15% 50~60Hz |
|
Input power (W) |
<150 |
|
Dimension (LxWxH) mm |
431x228x343 |
|
Net Weight (KG) |
< 15 |
Characteristics of the Products:
1.Electrolysis of low density lye(pure water and a very little alkaline)to produce hydrogen and the purity of hydrogen is extremely high.
2.Voltage of unit cell is low, and electric resistance in the electrolysis cell is little, giving out no heat, and cycle of changing desiccants is long, producing highly pure hydrogen.
3.With stable pressure and output, Hydrogen is controlled according to the requirements, and automatic control technology is perfect and reliable.
4.Power consumption is less, and the electrolysis is efficient.
5.H2 flow and pressure is stable
6.Japan imported AEM membrane







Technical Parameter of QL-500 gas chromatography use hydrogen generator
|
Type |
QL-500 |
|
Output Volume (ml/min) |
0~510 |
|
Output Pressure (MPa) |
0.15~0.4 |
|
H2 purity (%) |
>99.999 |
|
Protective Pressure (MPa) |
0.46 |
|
Power Voltage (V) |
220±15% 110±15% 50~60Hz |
|
Input power (W) |
<300 |
|
Dimension (LxWxH) mm |
431x228x343 |
|
Net Weight (KG) |
< 15 |
Characteristics of the QL-500 gas chromatography use hydrogen generator
1.Electrolysis of pure water (adding no alkali) to produce hydrogen with no corrosion and pollution, and the purity of hydrogen is extremely high.
2.Voltage of unit cell is low, and electric resistance in the electrolysis cell is little, giving out no heat, and cycle of changing desiccants is long, producing highly pure hydrogen.
3.With stable pressure and output, Hydrogen is controlled according to the requirements, and automatic control technology is perfect and reliable.
4.Power consumption is less, and the electrolysis is efficient.
5.H2 flow and pressure is stable
6.Titanium material
7.DuPont Nafion Membranes N-117
PEM hydrogen Technology working principle:
The proton exchange membrane (PEM), which only allows water and positive ions to cross between compartments. The membrane also serves as the electrolyte in the cell, eliminating the need for hazardous liquid electrolytes such as concentrated potassium hydroxide. PEM water electrolysis simply splits pure deionized water (H2O) into its constituent parts, hydrogen (H2) and oxygen (O2), on either side of this membrane. When a DC voltage is applied to the electrolyzer, water fed to the anode, or oxygen electrode, are oxidized to oxygen and protons, while electrons are released. The protons (H+ ions) pass through the PEM to the cathode, or hydrogen electrode, where they meet electrons from the other side of the circuit, and are reduced to hydrogen gas. The two reactions that occur in the cell are as follows:
2.2H2O -> 4H+ + 4e- +O2
3.4H+ + 4e- -> 2H2
4.Thus, the only possible components of the streams are hydrogen, oxygen and water moisture, as shown in
Figure 1 below.
Company Information
Shandong Saikesaisi Hydrogen is a 20 years laboratory gas generating equipment manufacturer.product reached ISO9001,CE certification.We are the earliest laboratory gas equipment exporter in China,till now,we have been 8 years golden member on .Our main product inlcude PEM pure water electrolysis h2 generator,KOH eletrolyte electrolysis h2 generator, Palladium tube h2 generator;PSA N2 generator, electro-catalysis method N2 generator;zero air generator,pure air compressor etc.




Please contact us if you have interest to our Instrument:
Kevin Zhang