Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography

Product Details
Customization: Available
Application Fields: Medical
Certification: RoHS, ISO, CE
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Full Customization
The supplier provides full customization services
R&D Capabilities
The supplier has 9 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
  • Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
Find Similar Products

Basic Info.

Model NO.
QL-500
Noise Level
Ultra Quiet
Parts
Filters
Purpose
Gas Manufacturing
Model
Ql-500
H2 Flow
500ml/Min
H2 Purity
99.999%
H2 Pressure
0-4 Bar
Application
Fid, Gc, Lab Usage
Power
AC100-120V or 200-240V
Dimension
42X23X36cm
Warrranty
12 Months
Certificate
Ce, ISO, SGS
Usage
Hydrogen
Machine Size
Small
Transport Package
Wooden Box
Specification
H2 flow: 500ml/min, purity: 99.999%
Trademark
Saikesaisi
Origin
Shandong, China
HS Code
8543300090
Production Capacity
300 Units/Month

Product Description

QL-500 hydrogen generator   

QL-500 hydrogen generator adopt SPE/PEM technology-top hydrogen tech in the world. PEM full name is Proton Exchange Membrane. Also called SPE technology ( solid polymer electrolyte).QL series hydrogen generator is our patented products, which are light , highly effective  energy-saving and of environmental protection, producing extremely pure Hydrogen (>99.9999%) through the electrolysis of pure water.


Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
 

Application:

1.GC (gas chromatography) fuel gas and carrier gas(replace h2 cylinder)

2.ELCD (conductivity detector) reaction h2 gas(replace h2 cylinder)

3.AED (atomic emission detector) of the reaction h2 gas(replace h2 cylinder)

4.Pure h2 gas supply for fuel cell

5.Other pure h2 using field

 

Technical Parameter:

Type QL-500
Output Volume (ml/min) 0~510

Output Pressure (MPa)

0.02~0.4

Pluctuation Rate of Output Pressure(%)

<0.1

H2 purity (%)

>99.999

Second Protective Pressure (MPa)

0.42

Power Voltage (V)

220±15%   110±15%    50~60Hz

Input power (W)

<200

Dimension (LxWxH) mm

431x228x343

Gross Weight (KG)

< 15

 

PEM hydrogen Technology working principle:

The proton exchange membrane (PEM), which only allows water and positive ions to cross between compartments. The membrane also serves as the electrolyte in the cell, eliminating the need for hazardous liquid electrolytes such as concentrated potassium hydroxide. PEM water electrolysis simply splits pure deionized water (H2O) into its constituent parts, hydrogen (H2) and oxygen (O2), on either side of this membrane. When a DC voltage is applied to the electrolyzer, water fed to the anode, or oxygen electrode, are oxidized to oxygen and protons, while electrons are released. The protons (H+ ions) pass through the PEM to the cathode, or hydrogen electrode, where they meet electrons from the other side of the circuit, and are reduced to hydrogen gas. The two reactions that occur in the cell are as follows:
2.2H2O -> 4H+ + 4e- +O2
3.4H+ + 4e- -> 2H2
4.Thus, the only possible components of the streams are hydrogen, oxygen and water moisture, as shown in 
Figure 1 below.


Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
 

 

Characteristics of the Products:

1.Electrolysis of pure water (adding no alkali) to produce hydrogen with no corrosion and pollution, and the purity of hydrogen is extremely high.

2.Voltage of unit cell is low, and electric resistance in the electrolysis cell is little, giving out no heat, and cycle of changing desiccants is long, producing highly pure hydrogen.

3.With stable pressure and output, Hydrogen is controlled according to the requirements, and automatic control technology is perfect and reliable.

4.Power consumption is less, and the electrolysis is efficient.

5.H2 flow and pressure is stable

6.Titanium material

7.DuPont Nafion Membranes N-117

 

Packaging & Shipping


Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
 


Ql-500 High Purity Lab Usage Pem Hydrogen Generator for Fid Gas Chromatography
 

 

Rick Hu
Shandong Saikesaisi Hydrogen Energy Co.,Ltd
Mobile:+86 13305312544
NO.1999 Dazheng Road, Gaoxin East District,Jinan,China 250104

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier