Qlc-1000 Pem Technology Electrolysis Cell

Product Details
Customization: Available
Warranty: 12 Months
Model: Qlc-1000
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Full Customization
The supplier provides full customization services
R&D Capabilities
The supplier has 9 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Qlc-1000 Pem Technology Electrolysis Cell
  • Qlc-1000 Pem Technology Electrolysis Cell
  • Qlc-1000 Pem Technology Electrolysis Cell
  • Qlc-1000 Pem Technology Electrolysis Cell
  • Qlc-1000 Pem Technology Electrolysis Cell
  • Qlc-1000 Pem Technology Electrolysis Cell
Find Similar Products

Basic Info.

Model NO.
QLC-1000
H2 Producing Rate
1000ml/Min
O2 Producing Rate
500ml/Min
Power Supply Requirement
DC12V, 35-45A
MOQ
1 Piece
Transport Package
Carton Box or Wooden Box
Specification
Dupont membrane
Trademark
Saikesaisi
Origin
China
HS Code
8543909000
Production Capacity
300 Units/Month

Product Description

       Hydrogen and Oxygen Electrolyzer of water  

                  -PEM titanum electroliser 

Product Introduction

QLC titanum electroliser is an advanced patented product, which are light , highly effective, energy-saving and of environmental protection , producing hydrogen and oxygen through the electrolysis of pure water (without adding alkali). That's PEM technology.  The PEM/SPE electrodes, as the core of titanum electroliser cell , are highly active catalytic electrode with nearly zero distance between the electrodes , which is formed by integrating composite catalyst with and ion membrane with high electrolytic efficiency.

 

Working Principle

 

Electrolytic water meeting the requirements (with electrical resistivity >1MΩ/ cm) , after being put into the anode chamber of electrolytic cell, when power is switched on ,will be decomposed at once at the anode : 2H2O = 4H+ + 2O-2. The decomposed negative oxyanion (O-2) will immediately release electron to form oxygen (O2) gas.The hydrogen proton, in the form of aqua ion (H+.XH2 O), and under the action of electric field force, through SPE ion membrane, will arrive in the cathode to absorb electron to form hydrogen gas.

 

Shape Structure

  Qlc-1000 Pem Technology Electrolysis Cell
   

 

1.Negative electrode  

2. Oxygen and water outlet

3. Positive Electrode

4.H2 outlet    

5.Fix Bracket

6.Water Inlet

 

Working Parameters

 

    model

Parameter

QLC-300

QLC-500

QLC-1000

voltage(DC)

3~5V

6~8V

12~15V

current(DC)

45A

36A

36A

H2 production

300ml/min

500ml/min

1000ml/min

O2 production

150ml/min

250ml/min

500ml/min

                                                       

       

Notice

 1, Electrolytic water must be deionized or secondary distilled water, water does not meet the standards will cause irreparable damage to the electrolytic tank.

 2, Connect the electrode line must be right.

3,  The electrolytic cell can not be drained for a long time. If the electrolytic cell is removed, a small amount of deionized water or secondary distilled water should be injected into it.

Qlc-1000 Pem Technology Electrolysis Cell
Qlc-1000 Pem Technology Electrolysis Cell

 

 

 

 

We are manufacture, we can make all kinds of custom-order product. 

 

please freely talk us if you ask further info:

 

Rick Hu
Shandong Saikesaisi Hydrogen Energy Co.,Ltd
 
 
 
 
NO.1999,Dazheng Road, Gaoxin East District ,Jinan City ,Shandong Province China

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier