• Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
  • Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
  • Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
  • Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector

Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector

After-sales Service: 1 Year
Warranty: 1 Year
Brand: Gc112
Customized: Non-Customized
Portable: Non Portable
Certification: CE
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (27)

Basic Info.

Model NO.
GC112N
Gas
CH4
Type
Electrochemical Gas Analyzer
Detector
Fid
Transport Package
Plywood
Origin
China
HS Code
9027201100
Production Capacity
200 Per Month

Product Description

Product Introduction
Gc112n Laboratory Gas Chromatography System Analytic Instrument Fid Detector
Features & Specification
Feature:
1.Standard PC side reverse control software
2.Host with 7-inch color touch screen
3.Gas shortage alarm protection function
4.Split flow/split ratio can be automatically controlled to save carrier gas.
5.Configure automatic sampler installation and positioning interface 
6.The multi-core, 32-bit embedded hardware system 
7.Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function
8.One-button start function
9.It has perfect system self-check function and fault automatic identification function.
10.With 8 external event extension function interface
11.RS232 communication port and LAM network port


Technical Specifications:
Column temperature box
Content product
22L
Temperature control range
5ºC ~ 400ºC at room temperature
Temperature control accuracy
±0.1ºC
Heating rate
0.1 ~ 60ºC / min
Program temperature rise order
9
Program heating repeatability
≤ 2%
Cooling way
open the door after
Cooling speed
≤10 mins (250ºC ~ 50ºC)
Control software function
(GC112N only)
Column temperature box control
Detector control
Injector control
Map display
Sampler
Temperature control range
7ºC ~ 420ºC at room temperature
Temperature control method
independent temperature control
Carrier gas flow control mode
constant pressure
Number of simultaneous installations
3 at most
Type of injection unit
filling column, shunt
Split ratio
split ratio display
Cylinder pressure range
0 ~ 400kPa
Cylinder pressure control accuracy
0.1kPa
Flow setting range
H2 0 ~ 200ml / min
N2 0 ~ 150ml / min
Detector
FID, TCD optional
Temperature control
Max. 420ºC
Number of simultaneous installations
2 at most
Ignition function
automatic
Hydrogen flame ionization detector (FID)
Detection limit
≤ 3×10 g/s (n-hexadecane)
Baseline noise
≤ 5× 10-14A
Baseline drift
≤ 6× 10-13A
Dynamic range
107
RSD
3% or less
Thermal conductivity detector (TCD)
Sensitivity
5000mV•mL/mg (n-cetane)
Baseline noise
≤ 0.05 mV
Baseline drift
≤ 0.15mV / 30min
Dynamic range
105
Supply voltage
AC220V±22V, 50Hz±0.5Hz
Power
3000W
 